Type | Item | Parameter |
Equipment Dimensions & Power | Power Input | 220V 50/60Hz |
| Pneumatic System | Compressed air flow >2LPM; System supply pressure 0.6MPa-0.7MPa |
| Vacuum System | Vacuum gauge reading ≤ -80kPa |
| Environmental Conditions | Temperature: 15-35°C; Humidity: standard 70% at 32°C; Cleanliness level: 100k Class |
| Machine Dimensions | 1150mm×1000mm×1850mm |
| Equipment Weight | 850-950kg |
| Safety Protection | Product Safety Protection | Contact grounding treatment |
| ESD Protection | Ion fan for electrostatic removal |
| Software Protection | Mistake proofing |
| Equipment Protection | Collision prevention, axis stroke limit, distance sensor |
| Operator Safety Protection | Protective goggles |
| Alignment Module | Operating module | 6-axis module |
Operating module Workpiece Clamping | Electric clamp, vacuum suction fixation |
Single-Axis Repeatability XYZ Drive Mechanism | ±0.05μm Step motor with ball screw |
| θx | Manual adjustment |
High-Precision Alignment Stage θy/θz | Automatic stage Repeatability: ±0.001° |
| Dispensing Module | Structural Configuration | Pneumatic extension dispensing supply (XY manual stage position fixation) |
| Dispensing Method | Bottom-side dispensing |
| Dispensing system | Musashi high-precision dispensing machine, single-point (needle), Standard 3mL capacity, other volumes customizable |
| Device Biasing Method | Socket connection | Automatic alignment |
Loading/ Unloading Module | FA Tray | Single MPO dual FA |
| PCB Tray | Single PCB tray with Pneumatic clamping |
| UV Curing System | UV type | HOYA dual LED light source; Wavelength 365nm |
| Operate axis | XYZ axis with air powered cylinder |
| Visual system | Number of Camera | 2 |
| Visual recognize | Automatic alignment;5 Megapixel CCD;Visual range 5.6×4.7mm;Resolution: 1.4 um;Depth of field: 0.3mm |
| Camera axis | XYZ 3 axis: step motor with ball screws |
| Alignment System | Alignment stability (Average Variance value) | <±5% |
| Level adjustment | Automatic alignment module |
| High adjustment | Pressure sensing |
| CT | < 180 sec/channel (Not including curing time, Depending on application scenario) |
| Software | Programming language | LabVIEW |
| Data binding | Capable to record production orders, product codes |
| Storage | Production data can be saved |
| Program calls | Program base can save multiple alignment programs to fit different alignment process |
| Power Meter | Meter type | Keithley E3646A (Can be modified according to requirements) |
| Voltage/Current range | Keysight (0-8V,3A/0-20V,1.5A) |
| Measure resolution | Voltage: <0.05% +5mV / Electric current <.15% + 5mA |
Laser Source
| Laser type | Santec(TSL-570A-P) (Can be modified according to requirements) |
| Performance | 200 nm/s quick scan High precision range(± 2 pm) & resolution(0.1 pm) The sealed cavity ensures the stability of each wavelength Multiple wavelength options from 1240 to 1680 nm Adjust scan range 10GHz |
Laser Power Meter
| Type | Santec MPM-220 series (Can be modified according to requirements) |
| Sensor performance | 840 - 1700 nm ,-80 - +8 dBm customize option |